zur Startseite der DMG-Lib
Home  · Übersicht  · Kontakt  ·

Erweiterte Suche   Mechanismensuche

CAPACITY P ICKUP MECHAN ISM FOR W O R K P IE C E INSPECTION

Ansicht vergrößernAnsicht vergrößern Beschreibung

Measuring spindle 1 slides in
guide b and bears against workpiece
a being inspected. S p in dle
1 moves capacitor plate 3
which is mounted on flat
spring 4. Movable plate 3 and
fixed plate 2 are the plates of
a capacitor whose capacitance
depends upon the size of the
workpiece. The change in capacitance
indicates the size of the
workpiece.
$4340$SmE,M$

Verknüpfte Datensätze
Dokumente: Hydraulic, pneumatic and electric mechanisms  [Streambook]
Permanentlinks
DMG-Lib FaviconDMG-Lib https://www.dmg-lib.org/dmglib/handler?image=10576023
Europeana FaviconEuropeana  http://www.europeana.eu/portal/record/2020801/dmglib_handler_image_10576023.html
Datenbereitsteller
UCAUniv. Cassino  http://webuser.unicas.it/weblarm/larmindex.htm
×