Description
Compressed air is delivered from the mains to port 1. Port 2 is connected to chamber 3 which, in turn, is connected to the atmosphere by a port (not shown). At the same time, air is delivered through channel 5 to ball valve 8. Channel 6 is connected to the atmosphere through holes drilled in armature 7 and through hole 9. When coil 10 is energized, the armature is pulled into the electromagnet and moves downward, overcoming the resistance of the spring. In the first part of this motion, the ball of valve 8 shuts off the central passage in the armature, disconnecting channel 6 from the atmosphere. In further motion of the armature, the ball of valve 8 is pushed downward, allowing air from channel 5 to enter channel 6. The pressure of the compressed air shifts plunger 4 downward, overcoming the resistance of the spring, and air from port 1 flows through port 1, which is disconnected from chamber 3. When coil 10 of the electromagnet is de-energized, armature 7 is raised by its spring, ball valve 8 closes and channel 6 is connected to the atmosphere. Then plunger 4 is returned by its spring to the position shown. Directional valves of this type are applied to control one way actuators (operating cylinders or devices). $4312$SmE,FC$
|