EMERGENCY-SYSTEM-CONTROLLED SHUTOFF VALVE MECHANISM |
|||||||
|---|---|---|---|---|---|---|---|
Premi per ingrandire
|
Description
When the emergency system is switched in, fluid flows in through port 1 and pushes plunger 2 to the right, overcoming the resistance of helical spring 6 and shutting off inlet port 3 of the main hydraulic system. The fluid flows through a recess in the valve body and holes 4 to port 5. |
||||||