| TAPER-SEAT RELIEF VALVE MECHANISM | |||||||
|---|---|---|---|---|---|---|---|
|    Click pentru a mări | Description 
                    When the pressure of the fluid in port 1 exceeds the preset value, controlled by the setting of the helical spring, sliding valve member 2 is lifted, overcoming the force exerted by the spring and allowing surplus fluid to flow out through port 4 to the receiver. The spring is regulated by screw 3. | ||||||