PNEUMATIC STYLUS MECHANISM FOR SURFACE ROUGHNESS MEASUREMENT |
|||||||
|---|---|---|---|---|---|---|---|
Click to enlarge
|
Description
Compressed air is delivered through pipe 1 and past valve 2 to channels a. As stylus d, held by spring 3 against surface b whose roughness is being measured, slides along surface b, the irregularities of surface b raise and lower the stylus and valve 2, varying the flow of compressed air in the system and its pressure. This pressure is continuously measured by a manometer. |
||||||