Click to enlarge
|
Description
Lever 7 turns about fixed axis A and is connected by turning pairs B and D to links 10 and 11. Link 10 is connected by turning pair C to the rod of piston 5, and link 11 by turning pair E to valve 3. When jet valve nozzle 1, turning about fixed axis F, is diverted by membrane 2 owing to an increase in pressure on the membrane, the spool of valve 3 is shifted, admitting fluid to move the piston of servomotor 4 and the piston of auxiliary servomotor 5. This compresses spring 6 and lever 7 shifts sleeve 8. Then, as the fluid flows from one end of the cylinder of auxiliary servomotor 5 to the other end through flow-control valve 9, the piston of servomotor 5 moves to the right and lever 7 returns valve sleeve 8 to its initial position. When the pressure drops in the right-hand chamber of membrane 2, the elements of the regulator operate in the reverse direction. $4096$EHP,Rg$
|