INDUCTANCE P ICK U P M ECH AN ISM FOR WORKPIECE INSPECTION

Click to enlargeClick to enlarge Description

Measuring spindle 1, contacting workpiece a being inspected,
slides in a hole of the pickup housing. Armature 2 is pressfitted
on spindle 1. Heavy cy lind rical magnetic circuit components
3, w ith inserted coils 5, are tig h tly fitted into the pickup
housing. The clearances between armature 2 and magnetic circuit
components 3 vary w ith the size of workpiece a. This varies
the inductance of the coils. The inductance is used as a measure
of workpiece size. S pring 4 provides the requiredj'measuring
force.