zur Startseite der DMG-Lib
Home  · Übersicht  · Kontakt  ·

Erweiterte Suche   Mechanismensuche

E L EC T ROD YN AM IC P R O F IL O M E T E R MECHAN ISM

Ansicht vergrößernAnsicht vergrößern Beschreibung

Movable cy lin d ric al coil /, wound with a large number of turns of copper
wire, moves in the radial magnetic field set up in the air gap of permanent
magnet 2 in accordance with the axial motion of stylus 3, rig id ly
secured to coil 1. Stylus 3 is moved at constant speed along surface a
being inspected. This induces an emf in coil /, which is proportional to
the velocity of its displacement. This emf in the coil is transmitted through
amplifier 4 to electric measuring and recording instrument 5.
$441$SmE,M$

Verknüpfte Datensätze
Dokumente: Hydraulic, pneumatic and electric mechanisms  [Streambook]
Permanentlinks
DMG-Lib FaviconDMG-Lib https://www.dmg-lib.org/dmglib/handler?image=11000023
Europeana FaviconEuropeana  http://www.europeana.eu/portal/record/2020801/dmglib_handler_image_11000023.html
Datenbereitsteller
UCAUniv. Cassino  http://webuser.unicas.it/weblarm/larmindex.htm
×